| Brand Name: | Cholly |
| MOQ: | 2000pcs |
| Price: | Negotiable |
| Delivery Time: | 10days |
| Payment Terms: | T/T, L/C |
This nickel sulfate FIBC bag uses a 180 g/m² externally coated PP woven body, 190 g/m² coated top and bottom panels, and an approximately 90 μm PE inner liner. The woven outer bag provides the structural layer, the coating reduces direct exposure through the woven openings, and the liner separates the nickel sulfate from the outer fabric and storage environment.
The configuration is suitable for filling, production-stage temporary storage, warehouse transfer, and transportation of nickel sulfate powder or crystalline material. Actual moisture-control performance also depends on liner closure, spout fastening, ambient humidity, transportation duration, and package integrity.
PP woven fabric contains openings between the woven tapes. For nickel sulfate and other chemical materials requiring controlled exposure and contamination management, uncoated woven fabric alone may not provide a complete isolation structure.
The bag body uses 180 g/m² externally coated material, while the top and bottom panels use 190 g/m² externally coated material. The coating covers the outer woven surface, reducing direct contact between the material and woven openings while making the outer surface easier to clean.
The base fabric is specified with a minimum strength of 1760 N in both the warp and weft directions. This value describes the directional strength requirement of the woven fabric, but fabric weight and strength alone do not determine moisture performance.
The bag contains a 200 × 340 cm PE liner with a specified thickness of 9 si, approximately 90 μm. The liner separates the nickel sulfate from the PP woven outer bag, reduces entry into the woven structure, and limits direct exposure to the external environment during normal storage and transportation.
The specified liner has a tubular open-top and open-bottom configuration. Its moisture-control performance therefore also depends on:
The coated outer bag and PE liner create a multilayer isolation structure, but the configuration should not be described as airtight, waterproof, or completely moisture-proof without test data.
Before filling, fully extend the PE liner and check that it is not twisted, folded, or trapped around the bottom discharge section. The Ø45 × 60 cm filling spout should match the filling equipment and keep the material entering near the center of the bag.
After filling, select the liner-closing method according to the material condition and temporary storage period. Nickel sulfate awaiting inspection, blending, or transfer should not remain open for extended periods in high-humidity, outdoor, or condensation-prone areas.
For open filling systems, control airborne dust, floor moisture, and ambient humidity, and close the inner liner and outer filling spout promptly after filling.
For warehouse storage and transportation:
The formulation contains 1% UV additive, but no outdoor exposure duration or ageing-test result is specified. The additive should therefore not be used as evidence for long-term outdoor storage.
| Parameter | Specification and Technical Note |
|---|---|
| Product | Nickel Sulfate FIBC Bag |
| Suitable material | Nickel sulfate |
| Specified load | 1000 kg |
| Finished dimensions | 93 × 93 × 105 cm |
| Body fabric weight | 180 g/m² |
| Top and bottom fabric weight | 190 g/m² |
| Coating | External coating on PP woven material |
| Warp fabric strength | ≥1760 N |
| Weft fabric strength | ≥1760 N |
| Lifting design | Four cross-bottom lifting belts positioned along the corners |
| Lifting-belt specification | 7 cm wide with an approximately 45 cm loop height |
| Lifting-belt strength | No separate value stated; confirm through belt and finished-bag testing |
| Liner material | PE |
| Liner dimensions | 200 × 340 cm |
| Liner thickness | 9 si, approximately 90 μm |
| Moisture-control structure | 180 g/m² coated body with PE inner liner |
| Filling spout | Ø45 × 60 cm |
| Discharge spout | Ø45 × 45 cm |
| UV additive | 1% |
| Anti-static additive | 2% |
| Applicable humidity range | Not specified; determine from closure, storage conditions, and validation |
| Recommended stacking level | Not specified; do not state a fixed level without finished-bag stacking tests |
Confirm whether the nickel sulfate is supplied as powder, crystals, or granules. Particle size, bulk density, flowability, and filling temperature affect the liner configuration and filling process.
Check the warehouse for high humidity, damp floors, roof leakage, and condensation caused by temperature changes. A coated body and conventionally tied liner may not be sufficient for extended storage in severe moisture conditions.
Short-distance internal transfer and long-distance sea transportation involve different periods of humidity exposure. For longer journeys, reconfirm liner thickness, closure method, pallet protection, and container condensation controls.
Confirm whether the material is filled through an open system, screw conveyor, gravity feeder, or enclosed pipeline. The equipment interface should match the Ø45 × 60 cm filling spout.
Confirm whether the material will be discharged by gravity, vacuum transfer, or manual assistance. The Ø45 × 45 cm discharge spout should match the downstream equipment and material flow characteristics.
Confirm whether the liner needs tying, heat sealing, independent fixing, or an extended opening. If a defined moisture-barrier performance is required, provide water-vapour transmission, seal-integrity, or packaging-validation requirements.
| Check Item | Current Configuration | Confirmation Before Ordering |
|---|---|---|
| Body fabric | 180 g/m² externally coated PP woven material | Suitability for particle size and packaging environment |
| Top and bottom | 190 g/m² externally coated material | Spout connection and bottom construction |
| Fabric strength | Warp and weft ≥1760 N | Test method and specimen dimensions |
| Inner liner | 200 × 340 cm PE, approximately 90 μm | Thickness, dimensions, and closure method |
| Moisture-control structure | Coated outer bag with PE liner | Whether a higher barrier level is required |
| Filling spout | Ø45 × 60 cm | Compatibility with filling equipment |
| Discharge spout | Ø45 × 45 cm | Compatibility with discharge equipment and material flow |
| Lifting belts | Four 7 cm wide cross-bottom belts | Belt strength and finished-bag testing |
| Storage humidity | No fixed range specified | Confirm from site conditions and validation |
| Transportation duration | Order-specific | Sea freight, rainy season, and container condensation |
| Stacking level | Not specified | Confirm using tests, pallet design, and storage conditions |
| Closure method | Order-specific | Tying, heat sealing, or another closing method |