| Brand Name: | OEM |
| Model Number: | CF-TD1250-EX |
| MOQ: | 500 Pieces |
| Price: | USD 9 - 28 / Piece |
| Delivery Time: | 15 - 20 working days after deposit received |
| Payment Terms: | T/T, L/C at sight, Western Union |
Quick answer: a Type D FIBC is a static dissipative bulk bag that releases charge into the surrounding air through quasi-conductive filaments, so it needs no grounding cable. This model is rated 1250 kg at a 5 to 1 safety factor in a 95 by 95 by 120 cm four panel body at 175 gsm.
Dust explosion zones tend to be the places where a fixed earth point is hardest to install: a temporary frame, a rented unit, a discharge station moved between buildings. A Type D bag is built for exactly that constraint, because the dissipative filaments in the fabric release charge without a cable, clamp or checklist step.
The mechanism is a controlled corona discharge at the fabric surface. Charge leaves through the filaments at a rate that keeps the surface below the level where a brush discharge can ignite a dust cloud, which is why the resistance sits in the dissipative range rather than the conductive range.
This 1250 kg four panel bag sits between the one tonne and two tonne sizes, which suits plants filling 1.2 tonne blend lots. At 175 gsm the wall is heavy enough for powders with a moderate bulk density and for repeated handling on pallet routes.
At a Glance| Parameter | Specification |
|---|---|
| Type | Type D static dissipative FIBC |
| Fabric weight | 175 gsm PP woven with conductive filaments |
| Safe working load | 1250 kg |
| Safety factor | 5 to 1 |
| Body dimensions | 95 x 95 x 120 cm |
| Surface resistance | below 1 x 10^8 ohm |
| Grounding | Not required |
| Inlet | 50 cm duffle with tie cord |
| Discharge | 40 cm spout with flap |
| Lifting loops | 4 corner loops, 35 cm free length |
The bag is used for powders that can form an explosive dust cloud while being filled or emptied: organic pigment, polymer and resin powder, plasticiser blends, sulphur free fine chemicals and dry powder coatings. It also suits mobile filling frames, drum replacement stations and sites where the earthing point is unreliable. Where the site has a fixed earth rail and a documented clamp procedure, Type C bags remain an option at a lower unit cost.
Frequently Asked QuestionsDoes a Type D bag need earthing?
A: No. The dissipative filaments release charge into the surrounding air, so there is no cable, clamp or earth point involved in the fill.
How is Type D different from Type B?
A: Type B bags have a low breakdown voltage but no dissipative or conductive path, so they are only used where no explosive atmosphere is present. Type D is specified where a flammable dust cloud can occur.
Can a Type D bag replace a Type C bag anywhere?
A: Usually yes for handling, but the site's risk assessment governs. Type D is chosen where grounding cannot be guaranteed; Type C stays valid where a verified earth procedure already exists.
What resistance level does the fabric hold?
A: Dissipative range below 1 x 10^8 ohm, measured with the IEC 61340-4-4 method on samples from each production lot.
Is performance affected by washing or wear?
A: The dissipative filaments are part of the woven structure rather than a surface coating, so folding and normal handling do not remove them. Bags are still inspected between fills like any other FIBC.
Sampled bags are proof loaded at five times the rated load, and surface resistance plus network continuity are checked before a lot is released. Bags are baled 50 pieces per bale with PP strapping and PE film wrap. We can include a short handling note for the filling team explaining that no earth clamp is used with this specification, which avoids the confusion that comes from switching between Type C and Type D bags on the same line.
Tell us the powder and how the filling frame is set up, and we will confirm whether Type D is the right choice or whether your site procedure already supports Type C.
Searched as a no grounding antistatic bulk bag, an explosive dust container bag or a 1250 kg Type D FIBC, this model is specified for zones where a cable cannot be used.